Features Benefits

Thin provisioning

Ensure the most efficient allocation of pooled capacity

Data protection:

  1. Snapshot
  2. Volume copy/Volume mirror
  3. Sync and async remote replication

Support the highest data availability and quick service restart after storage accidents

Four 6Gb/s SAS host ports

Best-in-class throughput power; ideal fit for bandwidth-demanding applications

Four 1GbE iSCSI ports

  1. Achieve remote replication through iSCSI ports 
  2. Achieve DAS/SAN consolidation to meet service level requirements of tier 1 applications on DAS and tier 2 applications on IP SAN

Accommodates twenty-four 2.5-inch drives in a 2U enclosure

Provides enterprise-class performance with high-density configuration

Green design:

  1. High-efficiency power supplies

  2. Intelligent multi-level drive spin-down technology

  1. 80 PLUS-certified power supplies delivering more than 80% energy efficiency

  2. In spin-down state, drives can save up to 60% of energy consumption

CacheSafe technology

Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage

Fault-tolerant hardware modules

Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure"

Expansion up to 144 HDDs

"Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need

Powerful management suite (SANWatch) support, including multi-pathing functions

  1. Easy management and monitoring of your subsystems anywhere, locally or remotely
  2. Recognize and manage redundant paths; support path failover and load-balancing

Multiple monitoring methods

Real-time problem detection and notification to achieve continuous operation

Host Ports

Four 6Gb/s SAS ports (2 per controller)
Four 1GbE iSCSI ports (2 per controller)

Storage Controller

Dual redundant controllers

Cache Memory

Default 2GB, up to 8GB

Drive Connectivity

  • 6Gb/s SAS connectivity

  • Accommodates 2.5-inch disk drives

  • S.M.A.R.T. support

  • NCQ support

  • Automatic bad-sector reassignment

  • Dedicated bandwidth to each connected drive

  • Drive buffer on/off switch

Supported Drives

  • 2.5” SAS SSDs – 200GB, 400GB

  • 2.5” SATA SSDs* – 100GB, 200GB, 300GB

  • 2.5” 10K RPM SAS drives – 300GB, 450GB, 600GB, 900GB

  • 2.5” 15K RPM SAS drives – 147GB, 300GB

  • 2.5” 7.200 RPM SATA drives* – 250GB, 500GB, 1TB

* MUX board required when using SATA drives

** For the latest compatibility details, please contact our sales representatives

Maximum Number of Drives

  • Per system: 24

  • Via JBOD: 144

Corresponding Expansion Enclosure

Please refer to Related Information

Form Factor

2U

RAID Functionality

  • Global, delicated or enclosure hot-spare

  • RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60

  • Online expansion by:
    - Adding new drives
    - Copying and replacing drives with drives of larger capacity

  • RAID migration

  • Configurable stripe size and write policy per system

  • Intelligent drive handling
    - In degraded mode: skips irreparable blocks to continue rebuild
    - In normal operation: data-block verification and repair

Data Services

  • Thin provisioning

  • Local replication **
    - Snapshot
    - Volume copy/ mirror

  • Remote replication*
    - Synchronous or asynchronous

** Available with Standard license and optional Advanced license

Green Design

  • 80 PLUS-certified power supplies delivering more than 80% energy efficiency

  • Intelligent multi-level drive spin-down

Availability and Reliability

  • Redundant, hot-swappable hardware modules

  • CacheSafe technology

  • Multi-pathing support (EonPath)

  • Device mapper support

Notification

Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and Skype. 

Management

  • Java-based SANWatch management software

  • RS232 serial port for local access to firmware-embedded utility

  • Automated cache flush and caching mode operation per enclosure status

  • Telnet and SSH system monitoring via Ethernet

  • Platform-independent firmware management GUI

  • LCD keypad panel for monitoring and access to all configuration options

  • Module status LED indicators: component presence detection & thermal sensors via I2C bus

OS Support 

  • Windows Server 2003

  • Windows Server 2008, 2008 R2 (including Hyper-V)

  • RedHat Enterprise Linux

  • SUSE Linux Enterprise

  • Sun Solaris

  • VMware

** For the latest OS support details, please contact our sales representatives.

Service and Support

All EonStor DS systems are shipped with 2-year Standard Service

  • Standard service:
    - Hardware warranty
    - Software update; 8x5 phone, web and email support

  • Upgrade/Extension service*:
    Replacement part dispatch on the next business day (up to 5 years)
    - Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day
    - Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours

* Optional

Power

  • Power supplies: Two 530W DC

  • AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)

  • Frequency: 47-63 Hz

Environmental

  • Temperature:

    • Operating: 0 to 40°C without BBU or CBM / 0 to 35°C with BBU or CBM

    • Non-operating: -40 to 60°

  • Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating

  • Relative humidity: 5 to 95% non-condensing, operating and non-operating

Dimensions

Without chassis ears / protrusions:
446mm (W) x 88mm (H) x 514mm (D)

Weight

Without HDDs:17.32kg (38.18lbs)

Package Dimensions

709mm (W) x 400mm (H) x 528mm (D)

The “Purchase Reference” feature enables customers to request a quote from Silvershine sales representatives. Please note that actual product orders and purchases are not processed via Silvershine's website. If you wish to order and purchase Infortrend products, please contact our sales representatives directly.

 

Please note the following:

"Default Included" means that a component is standard included in system orders. Customers may order additional units to serve as spare components.

System

DSB24SR22424AEonStor DS SAS&iSCSI-to-SAS 2U/24-bay ASIC667 Redundant RAID including 8xSAS-6G ports, 4xGbE ports, 2xSAS-6G Exp. ports, 2x1GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 24xHDD trays, 1xRackmount kit
DSB24SR22424BEonStor DS SAS&iSCSI-to-SAS 2U/24-bay ASIC667 Redundant RAID including 8xSAS-6G ports, 4xGbE ports, 2xSAS-6G Exp. ports, 2x2GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 24xHDD trays, 1xRackmount kit
DSB24SR22424CEonStor DS SAS&iSCSI-to-SAS 2U/24-bay ASIC667 Redundant RAID including 8xSAS-6G ports, 4xGbE ports, 2xSAS-6G Exp. ports, 2x4GB DDR-II, 2x(PSU+FAN Module), 2xBBUs, 24xHDD trays, 1xRackmount kit

Hard Disk Drive/Solid State Drive/MUX Board

9ACMUX3G-0010Required for accommodating SATA drivesMUX board, 2.5" HDD, exclusive for SAS 6G drive side dual-controller subsystems
H1090XB1XX1-0030HGST 2.5" SAS 6Gb/s HDD 900GB,10000RPM, 1 in 1 Packing
HESESSS2020-00301sTEC Enterprise 2.5 SAS 200GB MLC SSD, 1 in 1 Packing
HESESSS2040-00301sTEC Enterprise 2.5 SAS 400GB MLC SSD, 1 in 1 Packing
HESESSS2080-00301sTEC Enterprise 2.5 SAS 800GB MLC SSD, 1 in 1 Packing
HESH10S2120-00301HGST 2.5" SAS 6Gb/s HDD 1.2TB,10000RPM, 1 in 1 Packing
HESNSSA3010-00301Intel Enterprise 2.5" SATA 100GB MLC SSD (DC S3700), 1 in 1 Packing, 5-year warranty
HESNSSA3020-00301Intel Enterprise 2.5" SATA 200GB MLC SSD (DC S3700), 1 in 1 Packing, 5-year warranty
HESNSSA3040-00301Intel Enterprise 2.5" SATA 400GB MLC SSD (DC S3700), 1 in 1 Packing, 5-year warranty
HESNSSA3080-00301Intel Enterprise 2.5" SATA 800GB MLC SSD (DC S3700), 1 in 1 Packing, 5-year warranty
HEST10S2030-00301Toshiba 2.5" SAS 6Gb/s HDD 300GB,10000RPM, 1 in 1 Packing
HEST10S2060-00301Toshiba 2.5" SAS 6Gb/s HDD 600GB,10000RPM, 1 in 1 Packing

Data Service License

SOFT-DRSDS-0010EonStor DS Advanced Local Replication License (Snapshot and Volume Copy/Mirror)
SOFT-REMDS-0010EonStor DS Remote Replication License

Expansion Enclosure

DSB24SJ2000REonStor DS SAS-to-SAS 2U/24-bay Redundant JBOD including 4 x SAS-6G ports, 2x(PSU+FAN Module), 24xHDD trays, 1xRackmount kit
DSS12SJ2000REonStor DS SAS-to-SAS 2U/12-bay Redundant JBOD including 4 x SAS-6G ports, 2x(PSU+FAN Module), 12xHDD trays, 1xRackmount kit
DSS16SJ2000RDefault IncludedEonStor DS SAS-to-SAS 3U/16-bay Redundant JBOD including 4 x SAS-6G ports, 2x(PSU+FAN Module), 16xHDD trays, 1xRackmount kit

Service & Warranty

WTE2B24R-00102-year extended warranty for ES/ESDS B24x-R models

Cable/SFP Module

9270CmSASCab6-0030SAS external cable, SFF-8088 to SFF-8088, 170 Centimeters
9270CmSASCab7-0030SAS external cable, Pull type, SFF-8088 to SFF-8088, 50 Centimeters
9270CmSASCab8-0030Default IncludedSAS external cable, Pull type, SFF-8088 to SFF-8088, 120 Centimeters
9373AYCAB-0010Default IncludedDB-9 Y-cable for dual-controller subsystems; maintenance-free during controller failover/failback

HBA Card

BH1LSS210-0010HBA card, LSI SAS9200-8E, SAS 6G, Dual port, 1 in 1 package

Controller Module

8BBS24RF224A-0010RAID controller module, for ESDS B24S-R2242-4 subsystem, 1GB DDR-II RAM
8BBS24RF224B-0010RAID controller module, for ESDS B24S-R2242-4 subsystem, 2GB DDR-II RAM
8BBS24RF224C-0010RAID controller module, for ESDS B24S-R2242-4 subsystem, 4GB DDR-II RAM

Other Accessories

9373CBBU-0010Default IncludedBattery backup unit, Li-Ion, for EonStor G6 and ESDS series subsystems, BBU ID
9373CCBM-0010Cache backup module, Li-lon, Flash, for EonStor G6 and ESDS series subsystems, BBU ID
9373CFBM-0010Flash backup module, for EonStor G6 and ESDS series subsystems
9ACETRAY-0030Default Included2.5" Hard disk drive tray
9ACTRAYMUX3G-00102.5" Hard Drive tray w/MUX board, exclusively for dual-controller subsystems
9CCPSU-0010Default IncludedPower supply unit w/FAN module for ESDS 2U/24-bay subsystems, 530W capacity
9CCSLIDER36-0010Default IncludedSlide rail assembly, for 2U-24bay subsystems, 24”~36” rack depth
DDR2RECMA-00101GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems
DDR2RECMB-00102GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems
DDR2RECMC-00104GB DDR-II DIM module for EonStor G6/ESDS/ESVA subsystems